ASD应用于科研实验室Content
en
Airborne Surface Disinfection in laboratories
Research laboratories
Whether in research laboratories, test laboratories or clean rooms, disinfection is crucial to guarantee optimal performance and the accuracy of your results. Find out about Devea’s expertise in ASD in research laboratories.
Case study: log₁₀ 6 in an L3 lab
How can DEVEA technology meet the needs of research laboratories?
You handle chemicals or biological materials on a daily basis. Microorganisms can therefore contaminate surfaces, equipment, floors and also operators.
Disinfection is thus a crucial process in research laboratories. Airborne Surface Disinfection (ASD) is a terminal disinfection procedure. With our Phileas system coupled with O2Safe, we guarantee consistent results, replicability and the highest performance possible. The purpose of ASD in research laboratories is to protect your work environment and all of your employees.
For microbiological safety cabinets (MSC), routine and/or maintenance protocols are mandatory. Following consultation with industry experts and users, DEVEA provides 3 solutions to address the challenges of volume and disinfection efficiency.
Life animal science
In a research animal facility, and even more in a germ-free or gnotobiology facility, you cannot take the risk of contamination. Devea has an historical expertise in animal facilities, a trusted partner to researchers who are experts in bioburden control.
Research laboratory
Case study: Airlock transfert animal lab
ASD in research laboratories: a look into Devea’s solutions
Phileas uses the unique and innovative Microdrop technology.
The combination of Phileas machines and either O2Safe or Phileasafe® disinfectants guarantees the effectiveness of the disinfection. This O2Safe-Phileas® combo has been granted the Marketing Authorisation (AMM ANSES N. FR-2019-0071).
All tests required by the EN 17-272 standard have been performed by independent laboratories.
We offer a unique range of small volume solutions with Phileas® Genius (0.5 m3-5m3) and Phileas® 25 (1m3-40m3) to address your challenges.
Our ASD methodology for research laboratories
Identification of needs
We are careful to establish a diagnosis of the situation to identify the specific needs of our clients.
Machine selection
Following the diagnosis, we select the most suitable ASD machine.
Testing with chemical or biological indicators
Tests are carried out upstream before launching the complete hygiene process.
Replicability of tests
Tests are reproduced for best results.
Deployement
The complete ASD process can now be started.
Our goal is to provide research laboratories with an ultimate solution.
What are the outcomes od ASD in research laboratories?
One of the key advantages of our Phileas® system is that no human intervention is required. Disinfection can therefore be scheduled, remotely triggered and carried out at night in order to reduce the downtime of your research laboratory. Depending on your area of activity, disinfection frequency may vary. The destruction of micro-organisms is measured by log levels as established by European and National authorities. Each log level equals a reduction to the power of ten. In a number of practical cases and applications, the Phileas / O2Safe formula has shown results > log₁₀ 6, i. e. a 99.9999% efficiency
1. log₁₀ 5 bacteria (99,999%)
2. log₁₀ 4 spore (99,99%)
3. log₁₀ 4 virus (99,99%)
4. log₁₀ 4 fungi-yeast (99,99%)
5. log₁₀ 4 mycobacterium (99,99%)
Phileas®/O2SAFE guarantees optimal results with our 100% biodegradable O2Safe Biocide.zh-Hans
To help improve translation, feel free to suggest through Email.
适用于实验室的ASD
研究实验室
无论是在研究实验室、测试实验室还是无尘室中,消毒都是保证最佳性能和结果准确性的关键。了解 Devea 对在研究实验室中实施 ASD 的专业技术。
案例研究:在L3 实验室中进行 log₁₀ 6 消毒
Devea 技术如何满足研究实验室的需求?
您每天都在处理化学材料、生物材料。微生物会因而污染操作表面、设备、地面和操作员。
因此,消毒是研究实验室的一项重要工作。气载表面消毒(ASD)是一种末段消毒程序。采用 Devea 的 Phileas 系统与 O2Safe(消毒剂)组合方案,可确保获得一致的效果、可复制性和最高的性能。在研究实验室中实施 ASD 的目的是保护您的工作环境和所有员工。
对于微生物安全柜 (MSC),常规和/或维护流程是强制性的。遵从行业专家和用户的咨询意见,Devea 提供了 3 种解决方案,以应对处理量和消毒效率方面的挑战。
生命动物科学
在研究动物设施中,尤其是在无菌或无生物设施中,您无法承受污染造成的风险。Devea 在动物设施方面拥有悠久的专业知识,是生物负载控制方面的专家研究人员值得信赖的合作伙伴。
研究实验室
案例研究:气闸转移动物实验室
研究实验室中的 ASD:Devea 解决方案概览
Phileas® 采用独特创新的 Microdrop(微滴)技术。
Phileas® 设备与 O2Safe® 或 Phileasafe® 消毒剂的组合方案确保了消毒工作的有效性。此 O2Safe-Phileas® 组合已获得上市许可(AMM ANSES N. FR-2019-0071)。
EN 17-272 标准要求的所有测试均由独立实验室完成。
我们提供一系列独特的小容量解决方案,包括 Phileas® Genius(处理量为 0.5 - 5 立方米)和 Phileas® 25(1 - 40 立方米),以应对您的挑战。
我们针对研究实验室的 ASD 方法论
我们在研究实验室采用的 ASD 方法论与其他行业施行的相似。不过,MSC(微生物安全柜)或实验室空间消毒的过程可能有所不同。
需求识别
我们会审慎地对情况进行诊断,以确定客户的具体需求。
设备选型
我们依据诊断结果选择最合适的 ASD 设备。
化学或生物指标测试
在启动整个卫生流程之前,先进行测试。
测试的可重复性
重复测试以获得最佳结果。
部署
现在可以启动完整的 ASD 流程。
我们的目标是为研究实验室的专业人士提供最佳 ASD 解决方案!
ASD 在研究实验室中的实施效果如何?
我们的 Phileas® 系统的关键优势之一是无需人工干预。因此,可以计划、远程启动和执行消毒任务于夜间,以减少研究实验室的停机时间。消毒频率可能视作用区域而有所区别。生化消毒效果,按欧洲和国家权威机构的规定,依据对数水平进行衡量。每个对数级别相当于10的该次幂的减少量。在相当多真实案例和应用中,Phileas / O2Safe 组合方案的消毒效果超过 log₁₀ 6,即效率为 99.9999%。
1. 对细菌效果 log₁₀ 5(99.999%)
2. 对孢子 log₁₀ 4(99.99%)
3. 对病毒 log₁₀ 4(99.99%)
4. 对真菌、酵母菌 log₁₀ 4(99.99%)
5. 对分枝杆菌 log₁₀ 4(99.99%)